Project supported by the National Key Research and Development Program of China (Grant No. 2016YFA0302002), the National Natural Science Foundation of China (Grant Nos. 91736311 and 11574354), Strategic Priority Research Program of the Chinese Academy of Sciences (Grant No. XDB21010100), and the Youth Innovation Promotion Association of the Chinese Academy of Sciences (Grant No. 2016300).
Coriolis effect is an important error source in the weak equivalence principle (WEP) test using atom interferometer. In this paper, the problem of Coriolis error in WEP test is studied theoretically and experimentally. In theoretical simulation, the Coriolis effect is analyzed by establishing an error model. The measurement errors of Eötvös coefficient (η) in WEP test related to experimental parameters, such as horizontal-velocity difference and horizontal-position difference of atomic clouds, horizontal-position difference of detectors, and rotation compensation of Raman laser’s mirror are calculated. In experimental investigation, the position difference between 85Rb and 87Rb atomic clouds is reduced to 0.1 mm by optimizing the experimental parameters, an alternating detection method is used to suppress the error caused by detection position difference, thus the Coriolis error related to the atomic clouds and detectors is reduced to 1.1× 10−9. This Coriolis error is further corrected by compensating the rotation of Raman laser’s mirror, and the total uncertainty of η measurement related to the Coriolis effect is reduced as δη = 4.4 × 10−11.
Atom interferometer (AI)[1] is a new type of precision measuring instrument, which has been widely used in precision measurement of gravity,[2–11] gravity gradient,[8,12–14] rotation,[15–19] and test of weak equivalent principle (WEP).[20–29] Coriolis effect is an important error source in gravity measurement experiments using AIs.[11,30–34] To compensate the effect of the Coriolis effect in atom interferometry, several effective methods have been used in single-species AI-based gravity measurements. Peters et al.[33] used the interference signal itself to find the correct position of the detection region (where the Coriolis effect vanishes) by introducing additional, well-defined rotations. Louchet-Chauvet et al.[34] corrected Coriolis shift by carrying out measurements with opposite orientations with respect to the Earth’s rotation vector direction. Lan et al.[35] used a piezoelectric tube (PZT)-controlled tip-tilt mirror to regulate the orientation of the Bragg beam and compensate for the Earth’s rotation. Different from the configuration of the single-species AI, the dual-species AI used for WEP tests can achieve time- or space-synchronized interference measurement using different species atoms, which has good performance in common-mode-noise suppression. However, due to the differences in the initial positions and velocities of the dual-species atomic clouds, the Coriolis effect related to the horizontal motion of the atomic clouds is still a major error source in AI-based WEP tests.[21,22] In 85Rb–87Rb dual-species AI, we achieved common-mode-noise suppression by the four-wave double-diffraction Raman transition (4WDR) scheme,[24] which greatly reduced contributions from laser phase noise, ac Stark shift, and quadratic Zeeman shift. But, the Coriolis effect error, which was introduced by the small inconsistent of the centroid positions and velocities of 85Rb and 87Rb atomic clouds, was not effectively suppressed, the uncertainty of this error was as high as 2.9 × 10−8,[24] which was the largest error term in the experiment at that time. To effectively improve the precision of WEP test using the 4WDR dual-species AI, we study the suppression of the Coriolis error in this paper. We first theoretically analyze the phase shift factors related to the Coriolis effect in the 4WDR AI, then calculate the Coriolis errors related to the experimental parameters, such as the velocity differences, position differences of atomic clouds, the position differences of detectors, and the rotation rate of Raman laser’s mirror. Based on the analysis, we find experimental means to suppress the Coriolis effect. By optimizing the background magnetic field, the parameters of the cooling laser beams, and the loading time of the magneto-optical trap (MOT), the position difference between 85Rb and 87Rb atomic clouds is reduced. By using the alternating detection method (ADM), the uncertainty caused by the position fluctuation of the dual-species atomic clouds is suppressed. By two-dimensional (2D) rotation compensation for Raman laser’s mirror, the total uncertainty of η measurement related to the Coriolis effect is reduced to δη = 4.4 × 10−11.
To quantitatively investigate the Coriolis error in the 4WDR AI and provide guidance for experiments, we establish an error model to analyze the dependence of the Coriolis phase shift on the velocity, position of the atomic clouds, and the position of the detectors (the velocity and position discussed in this paper are in the horizontal direction), then theoretically simulate the performance of rotation compensation of Raman laser’s mirror.
The Eötvös coefficient in 85Rb–87Rb dual-species AI-based WEP test is[24]
The schematic diagram of a 85Rb–87Rb dual-species AI is shown in Fig.
In the local laboratory (Wuhan, 30.54°N) coordinate system, assume that the positive direction of the z-axis is upward along the plumb line. The y-axis is the direction of the unit vector in the horizontal plane from south to north, x-axis is the direction of the unit vector in the horizontal plane from west to east. Considering the Earth as a regular sphere, the rotation angular vector of the Earth is written as
In the experiment, the average velocity of the atomic clouds measured by a detector is related to the detection position.[33,37] To quantitatively describe the velocity distribution of atoms in the detection area, we directly calculate the probability of atoms in the detection area. At the initial moment, the state of atom can be described by the product of the initial velocity distribution and the initial position distribution. Assume the atoms are inside the detection area at time t, the convolution (that is the equivalent velocity distribution of the atoms in the detection area) of atom’s position and velocity can be obtained by full-space integration. Thus, we calculate the Coriolis phase shift in differential-measurement of gravity using dual-species AI under various atomic parameters and detection parameters.
The Coriolis effect was compensated by changing the orientation of Raman laser’s wave-vector in single-species AI.[35] Here, we apply this rotation compensation method to the dual-species AI. Consider that the incident Raman beam is reflected by a PZT-driven mirror. Let ki be the wave-vector of the incident beam, ko the wave-vector of the exit beam, and n the unit normal vector of the mirror, then ko = ki – 2(ki ⋅ n)n.[38] In the mirror coordinate system, the west–east diameter in the mirror surface is defined as x′-axis, and the diameter orthogonal to both x′-axis and n is y′-axis. When the 2D compensation angle (θx′,θy′) is applied to each Raman pulse, the compensated phase shift is
In the laboratory coordinate system, the actual rotation compensation performance can be evaluated by the contrast of interference fringes,[35] that is, when the fringe contrast reaches the maximum value, the corresponding mirror rotation rate just compensates the Earth’s rotation effect, the relevant phase shift is represented as
Due to the differences in mass and hyperfine levels, the average velocity, center position, size, and temperature of 85Rb and 87Rb atomic clouds are also different. Suppose the atoms are launched 2 m up and fall to the detection area after 1.2 s, the area of the detection is 10 mm × 10 mm, two detectors for 85Rb and 87Rb atoms are 30 mm apart, and the atomic clouds are symmetrically distributed in the vertical direction. We calculate the dependence of the Coriolis shift on the difference of the initial velocity and position between 85Rb and 87Rb atomic clouds.
The simulated error of η versus atomic cloud parameters is shown in Fig.
In practical experiment, when the size of the detection area is fixed, for ultra-cold 85Rb and 87Rb atomic clouds with an initial temperature of 10 nK, it is necessary to accurately control and reduce their velocity difference to suppress the Coriolis error. For cold atomic clouds with an initial temperature of several microkelvin, it is necessary to precisely control and reduce their position difference to eliminate the Coriolis error.
Since the Coriolis effect is proportional to the horizontal-velocity of the atomic clouds, different detecting position leads to a difference in horizontal-velocity selection. This detection effect[37] introduces a Coriolis error. Assuming 85Rb and 87Rb atomic clouds are detected simultaneously by two different detectors, we simulate the dependence of Δη on the position difference of detection, the results are shown in Fig.
To effectively correct the Coriolis errors introduced by the position fluctuation of atomic clouds, the initial position difference and initial velocity difference of dual-species atomic clouds, it is necessary to compensate the tilt angle of Raman laser’s mirror caused by the Earth’s rotation. Let Ωm represent the actual rotation rate of Raman laser’s wave vector around y-axis, the theoretically simulated relation between Ωm and the fringe contrast is shown in Fig.
The simulated dependence of Δη on mirror’s rotation rate is shown in Fig.
We also simulate the rotation compensation around y-axis for Raman laser’s mirror. The dependence of fringe contrast on the interval of Raman pulses (T) is shown in Fig.
The above simulations have three implications: (1) controlling and reducing the initial position and initial velocity differences of the atomic clouds is a necessary means to reduce the Coriolis error; (2) the ADM is useful to reduce the measurement error introduced by detection effect; (3) rotation compensation of Raman laser’s mirror is necessary for correcting the Coriolis error. The experimental setup and experimental results are described in detail as below.
In our previous experiments,[24,39] due to the difference between the initial velocities of 85Rb and 87Rb atomic clouds, the resulting Coriolis uncertainty was δη = 2.9 × 10−8.[24] To improve the positional coincidence of atomic clouds, reduce detection error, and effectively compensate the Coriolis effect, here we add a 2D-PZT turntable (PI S-330.2SH) to control Raman laser’s mirror. The experimental setup is shown in Fig.
The MOT simultaneously traps and launches up 85Rb and 87Rb atoms to form dual-species atom fountains. The height of the fountains is 2 m. During the launching process, the atoms undergo velocity-selection and state-preparation, they then enter the magnetically shielded region, where the 4WDR scheme is used to implement a dual-species AI. After the interference process, the 85Rb and 87Rb atoms fall into the detection area and are detected by two detectors. The duration of the first Raman pulse is 31 μs, the interval of the Raman pulses is adjusted to 203.164 ms, so that the offset phase difference between the dual-species interference fringes is 20.5π, this is helpful for fitting the actual phase difference between 85Rb and 87Rb atoms by the ellipse fitting method.[40]
To improve the coincidence of interference trajectories of the two species atoms, the background magnetic field, the frequency stability, and the intensity stability of the lasers are optimized. This makes the atomic cloud in the MOT closer to a sphere. In the experiment, the size of the 87Rb atomic cloud increases with MOT loading time t. When t = 2 s, the sizes of 87Rb and 85Rb atomic clouds are similar. When t > 5 s, the size of 87Rb atomic cloud is twice that of 85Rb. Therefore, the loading time of the atoms in the MOT is adjusted to 2 s, so that the position difference of the two species of atomic clouds is reduced to the order of 0.1 mm. Atoms undergo vertical-velocity-selection before they enter the interference area, the control accuracy of vertical-velocity is 0.2 mm/s. These means effectively reduce the influence of the Coriolis effect, wave-front distortion, gravity gradient, and other factors.
In the experiment, the detection error comes from several factors, such as the size and position of detection beam, the angle of fluorescence collection, and the installation accuracy of detectors. The installation accuracy of the two detectors in west–east direction is better than 1 mm, and that in south–north direction is greater than 1 mm. The angle of the detectors in south–north direction is evaluated and adjusted according to the fluorescence signal. Affected by the fluctuations of the magnetic field, laser frequency, and laser intensity, the positions of the atomic clouds fluctuate. To solve these problems, a real-time ADM is used. In the first detection cycle, detector A collects the fluorescence signal of 85Rb atoms, detector B collects the signal of 87Rb atoms; in the second detection cycle, the two detection beams are exchanged, and detector A collects the signal of 87Rb atoms, detector B collects that of 85Rb atoms. These two detection steps are performed cyclically, which effectively suppresses the error caused by detection and atomic clouds’ position.
The rotation compensation of Raman laser’s mirror is achieved by the 2D-PZT turntable. When π/2, π, and π/2 Raman pulses reach the mirror, their wave vectors are rotated 0, ΩmT, and 2ΩmT by adjusting the tilt angle of the mirror, respectively. Because the normal direction of the mirror is orthogonal to the x′- and y′-axis of the PZT, it has a cross angle of 45° to both y-axis (south–north direction) and z-axis (vertical upward). The minor angle error between the project of the y′-axis of the PZT and the y-axis affects the measurement accuracy. The laboratory is located 16 m underground, a laser gyroscope is used to calibrate the south–north direction with a positioning accuracy of 2°, the deviation between the projection of y′-axis in the horizontal plane and the y-axis is within 5° (limited by the error of the PZT installation and positioning).
To quantitatively calibrate the error caused by the mirror, rotation compensation is applied for the mirror around x-axis and y-axis. First, the rotation around y-axis is compensated to obtain the optimal compensation angle, then the rotation around x-axis is compensated. The compensation angle in x-axis is very small, but it causes excessive compensation in y-axis. Finally, the total compensated error is evaluated by considering the error in x- and y-axis, and the theoretical estimation of overcompensation in y-axis.
After 2D rotation compensation is performed on Raman laser’s mirror, the fringe contrast is significantly improved. The experimental results of fringe contrast versus mirror’s rotation rate are shown in Fig.
The experimental results of Δη versus the rotation rate of Raman laser’s mirror are shown in Fig.
Based on the above data, the uncertainty of rotation rate around y-axis is 0.025Ω0 and that of Coriolis error is 1.1 × 10−9/Ω0 × 0.025 Ω0 = 2.8 × 10−11; the uncertainty of rotation rate around x-axis is 0.021 Ω0 and that of Coriolis error is 1.6 × 10−9/Ω0 × 0.021 Ω0 = 3.4 × 10−11. The total uncertainty of Eötvös coefficient is δη = 4.4 × 10−11.
In summary, the Coriolis error in AI-based WEP test was analyzed theoretically and measured experimentally. An error model suitable for Coriolis effect in the 4WDR dual species AI was built, the contribution of key experimental parameters to the Coriolis phase shift was analyzed. The Coriolis phase shift introduced by position mismatch of atomic clouds and position difference of detectors was suppressed by the ADM, and the Coriolis error caused by the inconsistent initial velocity of the dual-species atomic clouds was corrected by compensating the rotation of Raman laser’s mirror, and the uncertainty of η measurement in 85Rb–87Rb dual-species AI-based WEP test was improved to δη = 4.4 × 10−11. The experimentally measured error terms are consistent with the theoretical simulations. In addition, the dependence of fringe contrast on 2D rotation compensation was simulated under the condition of free evolution time of 1 s, which will be of significance for long-baseline AI-based higher-precision WEP tests in future.
[1] | |
[2] | |
[3] | |
[4] | |
[5] | |
[6] | |
[7] | |
[8] | |
[9] | |
[10] | |
[11] | |
[12] | |
[13] | |
[14] | |
[15] | |
[16] | |
[17] | |
[18] | |
[19] | |
[20] | |
[21] | |
[22] | |
[23] | |
[24] | |
[25] | |
[26] | |
[27] | |
[28] | |
[29] | |
[30] | |
[31] | |
[32] | |
[33] | |
[34] | |
[35] | |
[36] | |
[37] | |
[38] | |
[39] | |
[40] |